Waterproofing

Polyurethane Waterproofing

Monneli Elastothane WP2

Two Components Elastomeric Polyurethane Waterproofing Coating

Uses
Odorless waterproofing system for bathrooms, swimming pools, kitchens, terraces, balconies, shower areas
Cold applied waterproofing for flat roofs and concrete structures, basement masonry, roof gardens, car parking
As a damp proofing course
back to Waterproofing
Technical Information
Product Description

ELASTOTHANE WP2 is a two component, solvent free, liquid applied Polyurethane based waterproofing coating. It cures upon reaction of its two components and the resulting membrane is high performance seamless elastomeric waterproofing.

Advantages

Solvent free, cold applied
When applied, forms a seamless leak proof membrane
Crack bridging
Full surface adherence on multi-substrate
Provides impermeable coating
Outstanding mechanical properties
High tensile strength and elongation
High abrasion resistance
Good chemical resistance
Versatile, ideal for applications in both new and old substrates

Packaging, Coverage / Consumption

ELASTOTHANE WP2 is packed in 4 and 15 Liter cans

Consumption: 1 m2/Liter at 1mm thickness

Shelf Life & Storage

Keep the product in dry and sheltered place at temperature between +5oC to +25oC. In these conditions and in closed original containers, the product will have a shelf life of 12 months.

Technical Properties
Properties

Results

Appearance

Grey (Other colors available on request)

Density at 25°C

1.45 kg/L

VOC

VOC 10.0 g/L

Solid Content

100%

Pot Life at 25°C

40 minutes

Elongation at Break (ASTM D412)

180%

Tensile Strength (ASTM D412)

> 5 N/mm2

Modulus of Elasticity (ASTM D412)

0.6 N/mm2

Bond Strength (ASTM D412)

> 2 N/mm2

Shore A Hardness (ASTM D2240)

75

Crack Bridging (ASTM C 1305)

1.5 mm

Depth of water penetration (BS EN 12390)

No penetration after applying water pressure of 300 kPa at 72 Hours

Application Surface Temperature

+5°C to +35°C

Drying Time

24 hours

Complete Curing

7 days

Service Temperature

-5°C to +80°C

Application Information
Instructions for use

Crack treatment

Shrinkages and non-moving structural cracks less than 1.0mm shall be filled with a pre-treatment strip of ELASTOTHANE WP2 of 1.0mm thick extended to 75 mm on both sides of the crack. Voids and honeycombs shall be patched with BETOFINISH C or EPOFINISH C allowing the area to cure before applying the membrane.

Right angle bends

All right angle bends must have a coving detail installed. In areas where parapet walls, columns, pipe penetrations are present, a 45° coving fillet shall be made at all corners using BETOCEM FIBER, a Fiber reinforced shrinkage controlled mortar for concrete repair to the water saturated cured surface.

All other angles, joints, protrusions and stress joints should be pre-treated with a heavy application of ELASTOTHANE WP2 extending 150mm on both sides of the coving.

Movement Joints

Expansion and movement joints should be sealed with ELASTOSEAL PU, a Polyurethane sealant. When cured a stripped layer of ELASTOTHANE WP2, 200mm wide shall be applied and centered over all the sealed joints. While the membrane is still wet, ncover with a correct cut strip of fiber mesh, then apply another coat of ELASTOTHANE WP2 until it is fully covered. Allow to cure before the general application.

Priming

Highly porous concrete or concrete containing microsilica will be sealed using Primer PU, a Polyurethane primer. The primer shall be applied at a rate of 5-6 m²/L.

The primer should be left to achieve a tack-free condition for 6-8 hours before applying the top coat. A second coat of primer may be required if the substrate is excessively porous.

Mixing

ELASTOTHANE WP2 is supplied in two pre- weighed packs (Base (A), Hardener(B)), ready for onsite mixing. Mixing should be carried out using a heavy
duty, slow speed drill fitted with mixing paddle. The contents of base (part A) should be thoroughly stirred to disperse any possible settlement. The entire contents of the hardener can should be stirred and added to the base container.

Mix thoroughly for 2-3 minutes taking extra care to avoid air entrapment. Mix until a homogeneous mixture is attained.

Improper mixing may result in product failure. Once mixed, the material must be used within its pot life.

Application

ELASTOTHANE WP2 can be applied by brush, roller or airless spray. Subsequent layers could be done only after the first layer has been cured tack free (min 16 hours). In below ground structures, wet areas and roofs, the application thickness should not be less than 1.2mm. All liquid application should be in at least two coats. It should be ensured that the material is not applied at excessive film thickness in single layer. Excessive film thickness may create bubbles.

A layer of ARMOFLEX, a fiber glass mesh should be embedded between the two ELASTOTHANE WP2 coats over pipe culverts, floor drains, corner joints and floor / wall junctions.

The final wet coat of ELASTOTHANE WP2 shall be spread with sufficient clean silica and before applying tile adhesives. Tiling or finished floor installations
should be carried out as soon as possible after full cure of membrane is established.

Cleaning

Clean all the tools and application equipment with water immediately after use. Hardened or cured material can only be removed mechanically.

Recommendations

  • ELASTOTHANE WP2 should not be applied on surfaces with a risk of rising dampness

  • Don’t apply the product with imminent rain forecast.

  • Don’t mix more material than can be used within the pot life of mixture

  • Incorrect assessment treatment of cracks may lead to a reduced service life and reflective cracking

  • ELASTOTHANE WP2 is not designed to be exposed in external applications

  • Apply only when substrate and ambient temperature exceeds +5°C. During application the surface temperature must be +3°C above dew point.

Surface Preparation

The surface of the concrete shall be sound, clean and uncontaminated.

This preparation shall be such as to leave a sound exposed concrete surface free from dust, loose particles and any deleterious matter. If the concrete surface is defective or has laitance, it must be cut back to a sound base.

Oil, grease, varnishes, rust, dust and mould on metal surfaces shall be removed by wire or stiff brushing and grit blasting then wiped with SOLVENTE 10 prior to priming.

New concrete or cementitious surfaces should be at least 28 days old and have moisture content not mexceeding 5%. Old or existing surface should be refurbished mechanically to ensure clear and sound substrate.

Additional Information
Health & Safety

During application, wear appropriate protective clothing, goggles, gloves and respiratory equipment if necessary.

In case of contact with skin, rinse with water and again wash thoroughly with soap and water. In case of contact with eyes, rinse with plenty of water and seek medical advice accordingly.

If ingested, obtain medical attention immediately. Do not induce vomiting.

Important note

The information in this Technical Data Sheet is based on Colmef Monneli’s experience. Colmef Monneli does not accept any liability arising from the use of its products as it has no direct or continuous control over where or how its products are applied. All Colmef Monneli’s Data Sheets are updates on regular basis. It is the user’s responsibility to obtain the latest version.

additional materials
Fast Download
Technical Properties Sheet
download (*.pdf 0.07Mb)
OTHER PRODUCTS
More Products from this section
Monneli Elastothane 100

Elastomeric Single Component Aliphatic Polyurethane Waterproofing Membrane

Monneli Elastothane 400

Elastomeric Single Component Polyurethane Waterproofing Membrane

Monneli Elastothane TR2

Pitch Elastomeric Two Component Polyurethane Waterproofing Membrane

Monneli Elastothane TRX

ELASTOMERIC POLYURETHANE LIQUID APPLIED WATERPROOFING MEMBRANE

Monneli Elastothane WP1

Elastomeric Single Component Polyurethane Waterproofing Membrane

view more
RANDOM PRODUCT
Monneli Epochim K 100

High Chemical Resistant Epoxy Coating

Uses
A resistant coating against chemicals. It also acts as an abrasion protective coating for floors and walls and aggressive products, stored in metallic or concrete tanks