Waterproofing

PVC MEMBRANES FOR ROOF APPLICATIONS

Monneli Insuwrap 1500 WM-FB

1.5 mm thick with Fleeceback PVC Membrane for covered roofing system

Uses
Waterproofing of covered Roofs and podiums
back to Waterproofing
Technical Information
Product Description

Insuwrap 1500 WM-FB is a homogeneous PVC (polyvinylchloride) sheet waterproofing membrane with a calendared geotextile layer on the back.

Appearance: PVC rolled sheet membrane
Membrane thickness: 1.50mm + Felt
Colour: White, Twin Colors

Advantages
  • High tensile strength and elongation
  • Hot air weldable
  • Flexible throughout life span
  • Resistant to ageing
  • Long durability
  • High dimensional stability
  • Anti-Root membrane
  • Can be installed on wet and dry substrates
  • Designed to be used in hot climates
  • Reaction to Fire - Class B
  • Covered Application
Compiliance Standard

Tested according to testing requirements of ASTM D4434 and DIN 16730.

Packaging, Coverage / Consumption

Roll size: 2.10 m (roll width) x 20m (roll length)

Shelf Life & Storage

Rolls shall be stored in their original package, in horizontal position and under cool and dry conditions protected from direct sunlight and rain.

Insuwrap PVC membrane does not expire and has a very long life expectancy.

Ambient Air Temperature: +5°C - +60°C

Technical Properties
Test Performed Standard Requirements Results
Membrane Thickness ASTM D 4434 1.5 + Felt
Mass DIN16730 2.10 kg/m2
Tensile strength DIN 16730
Min 10.40 N/mm2
≥15.0 N/mm2
Elongation at break DIN 16735
Min 150%
>300%
Thermal Stability DIN 16735
Less than 1%
(6 hrs - 90°C)
<1.0%
Tear Strength Min 80 N > 125N
Seam Strength ASTM D 4434 >82%
Tear Resistance ASTM D 4434 >95 N
Puncture Resistance DIN 16735
Drop hammer 500 grams, from
300mm no leak
Passed
Water Vapour diffusion
Resistance
DIN16735
Less than 30,000
<22,000 μ
Cold Bend DIN 16735
No cracks at -20°C
No cracks at -30°C
Resistance to Algae &
Rot
  High resistance
Roots penetration No roots penetration No penetration, Growth dies
off
Fire Class DIN 4102 Pass (Class B2)
Application Information
Instructions for use

Substrate Preparation

The surface of the sloping concrete shall be sound, clean, dry or wet, and uncontaminated. This preparation shall be as such as to leave a sound exposed concrete surface free from dust, laitance and any delirious matter.

Application

PVC FLEECE BACK SHEET INSTALLATION (FULLY BONDED SYSTEM)

Install fleece back PVC sheets over entire r o o f area so the light colour is at the visible side and the fleece back towarsd the substrate.

A. Horizontal Installation:

  1. Install the separation layer over the entire horizontal area before the PVC membrane (if needed) in full accordance with Colmef’s method statement
  2. Accurately align sheets and maintain uniform side and end laps of minimum dimensions required. Stagger end laps.
  3. Install the Geotextile membrane as a separation layer above the PVC membrane followed by a minimum of 50mm extruded polystyrene thermal insulation
  4. As much as practically possible the joints will not be against the direction of flow.

B. Upstands:

  1. Apply the 1500 WM-UV membrane directly on the concrete up-stand with Neofil S10 contact adhesive.
  2. Secure top termination of waterproofing with continuous, Aluminum flashing strip, and Elastoseal PU25, a Polyurethane sealant from Colmef.

C. Seam Installation: Hot air welding and end laps of overlapping sheets according to manufacturer's method statement to ensure a watertight seam installation. Inspect outside edge of seams with pointed metal probe and ensure completed laps lay flat through one of the following methods:

  1. Method 1: All seams of installed waterproofing can be subject to pneumatic test at test pressure of 2.00 bars.
  2. Method 2: Testing the welded joint using a vacuum test machine

D. Any hole, resulting from construction activities, noted in installed membrane shall be repaired in accordance with manufacturer’s method statement.

CORNER JOINT INSTALLATION

A. Install corner details in accordance to waterproofing manufacturer's written instructions.

  1. Use same welding system as specified for membrane.
Limitation
  • Do not directly apply the PVC membrane permanently on bitumen and plastics other than PVC, a separation layer of geotextile is required.
  • The PVC membrane can be exposed to temporary UV light for a period of 6 months
  • Insuwrap 1500 WM-FB can be exposed temporary to ground water or polluted water with temperature up to 50°C for 3 months.
Additional Information
Health & Safety

Local safety regulations must be observed. Information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet.

Important note

The information in this Technical Data Sheet is based on Colmef Monneli’s experience. Colmef Monneli does not accept any liability arising from the use of its products as it has no direct or continuous control over where or how its products are applied. All Colmef Monneli’s Data Sheets are updated on regular basis. It is the user’s responsibility to obtain the latest version.

additional materials
Fast Download
Technical Properties Sheet
download (*.pdf 0.20Mb)
OTHER PRODUCTS
More Products from this section
Monneli Insuwrap 1000 WM-FB

1.0 mm thick with Fleeceback PVC Membrane for covered roofing system

Monneli Insuwrap 1200 WM-FB

1.2 mm thick with Fleeceback PVC Membrane for covered roofing system

Monneli Insuwrap 1200 WM-R

1.2 mm thick reinforced PVC Membrane for covered roofing system

Monneli Insuwrap 1200 WM-UV

1.2 mm thick PVC Membrane for exposed roofing system

Monneli Insuwrap 1200-WM

1.2 mm thick PVC Membrane for covered roofing system

view more
RANDOM PRODUCT
Monneli Insuwrap 1200 WM-FB

1.2 mm thick with Fleeceback PVC Membrane for covered roofing system

Uses
Waterproofing of covered Roofs and podiums
Contact us
Choose a location
P.O. Box: 123808, Dubai
Toll: +971 4 8803488
Fax: +971 4 8803450
Site Map