Waterproofing

PVC MEMBRANES FOR SUBSTRUCTURE APPLICATIONS

Monneli Insuwrap 3000 TNL-FB

3.0 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

Uses
Waterproofing of basements, tunnels and other underground structures
back to Waterproofing
Technical Information
Product Description

Insuwrap 3000 TNL-FB is a homogeneous PVC (polyvinylchloride) sheet waterproofing membrane with a calendared geotextile layer on the back.

Appearance: PVC rolled sheet membrane
Membrane thickness: 3.0 mm + Felt
Colour: White, Twin Colours

Advantages
  • High tensile strength and elongation
  • Hot air weldable
  • Flexible throughout life span
  • Resistant to ageing
  • Long durability
  • High dimensional stability
  • Anti-Root membrane
  • Can be installed on wet and dry substrates
  • Designed to be used in hot climates
  • Resistant to natural aggressive mediums in ground water soil
  • Time and cost efficient
  • Reduces the wrinkles in the geotextile layer
  • Eliminates the risk of burning he geotextile under the PVC membrane during the welding process
  • Minimize the risk of overlaps in geotextile
Compiliance Standard

Tested according to testing requirements of DIN 16938, DIN 16730, ASTM D3083 and SIA280/10,11,12,15.

Packaging, Coverage / Consumption

Roll size: 2.10 m (roll width) x 20m (roll length)

Shelf Life & Storage

Rolls shall be stored in their original package, in horizontal position and under cool and dry conditions protected from direct sunlight and rain.

Insuwrap PVC membrane does not expire and has a very long life expectancy.

Ambient Air Temperature: +5°C - +60°C

Technical Properties
Test Performed Standard and Requirements Results
Membrane Thickness (mm)   3.0 + Felt
Tensile Strength
Machine Direction
Perpendicular Direction mpA
ASTM – D638
DIN 16730
10.40 N/mm2
≥15.0 N/mm2
Elongation at Break (%) ASTM – D638
DIN 16730
>300%
Tear Strength (N) DIN 16730
80N (Min)
>100N
Thermal Stability DIN 16730
90°C -6 hours
Change less than 2%
<0.7%
Hardness Shore A (3 seconds) ASTM D2240 78
DIN 16730
80±1
Cold bend DIN 16730
No cracks at -20 °C
No Cracks at -30 °C
Water Vapour diffusion resistance (μ) DIN 16730
Less than 30,000
>21,000 μ
Tensile Strength Modulus Perpendicular
(Psi)
ASTM D638
DIN 16730
1210 Psi
100% Modulus Machine Direction (Psi) ASTM D638
DIN 16730
730
100 % Modulus Perpendicular Direction
(Psi)
ASTM D638
DIN 16730
730
Specific Gravity ASTM D792
DIN 16730
1.28
Compressive Strength SIA V 280/14  Passed
Puncture Resistance DIN 16730
Drop hammer 500 grams, no leak on falling from 300 mm
Passed
Impact Strength DIN 16726/15.12 >800mm
Resistance to Algae & Rot High resistance High resistance
Application Information
Instructions for use

Substrate Preparation

The surface of the concrete substrate shall be sound, clean, dry or wet, and uncontaminated.

This preparation shall be as such as to leave a sound exposed concrete surface free from dust, laitance and any delirious matter.

The granite surface must not contain broken aggregates. Any leaks shall be sealed with Murex, a water plug mortar, or with Betocryl 60, a Polyurethane injection resin. The surface of the granite and fine sprayed concrete must be cleaned (no loose stones, nails, wires, etc.).

Application

PVC FLEECE BACK SHEET INSTALLATION (FULLY BONDED SYSTEM / LOOSELY LAID SYSTEM)

A. General: Install Fleece back sheets over entire area in full accordance with manufacturer's method statement.

  1. Install membrane so that the PVC is at the visible side and the fleece back is towards the substrate.

B. Horizontal Installation:

  1. Adhere the fleece back PVC membrane (fully bonded) using Neofil S10 adhesive to the entire horizontal area or keep it loosely laid ( as per the project specs).
  2. Accurately align sheets and maintain uniform side and end laps of minimum dimensions required. Stagger end laps.
  3. Install the Geotextile membrane as a protection layer over the entire area above the fleece back PVC membrane followed by a minimum of 50mm cementitious screed

C. Vertical Applications:

  1. Adhere the fleece back PVC membrane (fully bonded) using Neofil S10 adhesive to the entire vertical area or keep it loosely laid (as per the projects specs).
  2. Accurately align sheets and maintain uniform side and end laps of minimum dimensions required. Stagger end laps.
  3. Install the protection layer of Geotextile membrane above the PVC membrane over the entire vertical area in full accordance with manufacturer’s method statement
  4. Secure top termination of waterproofing with continuous, PVC coated aluminium strip, and a suitable PU sealant from Colmef’s joint sealant product range.

D. Seam Installation: Hot air welding and end laps of overlapping sheets according to manufacturer's method statement to ensure a watertight seam installation. Inspect outside edge of seams with pointed metal probe and ensure completed laps lay flat and are free of voids, fish mouths, or wrinkles using one of the following methods:

  1. Method 1: All seams of installed waterproofing can be subject to pneumatic test at test pressure of 2.00 bars.
  2. Method 2: Testing the welded joint using a vacuum test machine

E. Any hole, resulting from construction activities, noted in installed membrane shall be repaired in accordance with manufacturer’s method statement.

CORNER JOINT INSTALLATION

A. Install corner details in according to waterproofing manufacturer's written instructions.

  1. Use the same welding technique as specified for membrane.
Limitation
  • Do not directly apply the PVC membrane permanently on bitumen and plastics other than PVC, a separation layer of geotextile is required.
  • The PVC membrane can be exposed to temporary UV light for a period of 6 months
  • Insuwrap 3000 TNL-FB can be exposed temporary to ground water or polluted water with temperature up to 50°C for 3 months.
Additional Information
Health & Safety

Local safety regulations must be observed. Information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet.

Important note

The information in this Technical Data Sheet is based on Colmef Monneli’s experience. Colmef Monneli does not accept any liability arising from the use of its products as it has no direct or continuous control over where or how its products are applied. All Colmef Monneli’s Data Sheets are updated on regular basis. It is the user’s responsibility to obtain the latest version.

additional materials
Fast Download
Technical Properties Sheet
download (*.pdf 0.20Mb)
OTHER PRODUCTS
More Products from this section
Monneli Insuwrap 1200 TNL-FB

1.2 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

Monneli Insuwrap 1500 TNL-FB

1.5 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

Monneli Insuwrap 2000 TNL-FB

2.0 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

Monneli Insuwrap 2200 TNL-FB

2.2 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

Monneli Insuwrap 2500 TNL-FB

2.5 mm thick Fleece-back PVC Membrane for Underground Structures & Tanking System

view more
RANDOM PRODUCT
Monneli Insuwrap 1000 WM-FB

1.0 mm thick with Fleeceback PVC Membrane for covered roofing system

Uses
Waterproofing of covered Roofs and podiums
Contact us
Choose a location
P.O. Box: 123808, Dubai
Toll: +971 4 8803488
Fax: +971 4 8803450
Site Map