Re-Injectable Hose Waterstop System
ELASTOJOINT RHS is a unique re-injectable hose system that ensures secure, simple and rapid sealing of horizontal and vertical construction joints which in turn eliminates the need for welding and installation of water bar and does not deteriorate over time.
ELASTOJOINT RHS is designed specifically to provide a resilient, hardwearing and optimum resistant construction joint even when permanently immersed in ground water, sewage, alkalis, saline, acids, petrol, diesel and alcohol.
Packaging | ||
Injectable Hose: | 100 linear meter /carton | |
Shutter Connector: | 20 pcs/carton (red & yellow stripes) |
Storage:
Keep the product in dry, covered shed and must be stored in place where temperature is above 0°C.
|
Surface preparation
The surface of the concrete shall be flat, dry, smooth, sound, clean and uncontaminated. This preparation shall be such as to leave a sound exposed concrete surface free from dust, loose particles and any deleterious matter. If the concrete surface is defective or has laitance, it must be cut back to a sound base.
Oil, grease, varnishes, rust, dust and mould on metal surfaces shall be removed by wire or stiff brushing and grit blasting then wiped with SOLVENTE 10 prior to priming.
Moss and lichen must be removed physically followed by treatment with fungicidal wash. After treatment, it must be washed down thoroughly with clean water and allow to dry.
Voids and honeycombs shall be patched with EPOFINISH C or BETOFINISH C allowing the area to cure before installation.
Installation
The hose shall allow for vacuuming operations, water cleaning and multiple / repeated use. The construction of the hose shall permit free discharge of the specified injected grout into the concrete for the entire length of the hose.
The system should be suitable for multiple reinjections over the whole life of the structure. The contractor shall submit detailed hose layouts to reflect the construction sequence and joint locations.
The hose installation shall be carried out without any cuts and joints when installed at multiple bends, corners or around congested reinforcement. The hose shall be capable of following infinite changes in direction and turn corners with ease.
The hoses shall be fitted with vent ends in lengths to suit field-measured conditions, with a maximum of 10 linear meters for each hose, including vent ends. Inlet and outlet PVC vent ends shall be reinforced, colour-coded (for identification), internally connected to the re-injectable hose and secured to it with shrink-on sleeves or special shutter connectors.
ELASTOJOINT RHS shall not be fixed at intervals longer than 15cm. Inlet and outlet vents shall terminate in junction boxes that shall be heavyduty plastic made for embedment in concrete and of adequate size for housing and protection of the injection hose vent ends. Boxes shall be securely fitted with temporary “knock-out” covers to be used during concreting operations. Where exposed, boxes shall be fitted with covers mounted flush with the surrounding area.
Recommendations
There are no health hazards in connection with ELASTOJOINT RHS in normal use.
The information in this Technical Data Sheet is based on Colmef Monneli’s experience. Colmef Monneli does not accept any liability arising from the use of its products as it has no direct or continuous control over where or how its products are applied. All Colmef Monneli’s Data Sheets are updates on regular basis. It is the user’s responsibility to obtain the latest version.
Flexible PVC Waterstop
PVC Elastomeric Waterproofing Tape
FLEXIBLE RE-INJECTABLE HOSE WATERSTOP SYSTEM
Hydrophilic Swellable Waterstop Joint Profile
Fixing glue / Joint Sealant